4-22
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 4 Perform Node Acceptance Tests
NTP-G44 Perform the Anti-ASE Hub Node Acceptance Test
Step 15 Complete the “DLP-G79 Verify the OPT-BST Amplifier Laser and Power” task on page 4-40 for the
east OPT-BST amplifier.
Step 16 Repeat Steps 9 through 15 for the remaining wavelengths on the 100-GHz grid that are pass-through
wavelengths.
Step 17 If you have add and drop channels, continue with Step 18 to verify the channels. If not, continue with
Step 29.
Step 18 Set the tunable laser or TXP_MR_1.5G card to the first wavelength of the 100-GHz ITU-T grid that is
not a pass-through wavelength. Refer to the tunable laser manufacturer’s documentation or the
“DLP-G268 Provision TXP_MR_2.5G Cards for Acceptance Testing” task on page 4-4.
Step 19 Connect the tunable laser or TXP_MR_1.5G card to the CHAN RX nn port on the west 32MUX-O,
where nn is the first add or drop channel.
Step 20 Display the west 32MUX-O in card view.
Step 21 Click the Provisioning > Optical Chn > Parameters tabs.
Step 22 Change the Admin State of Port nn to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 23 Check that the power value on Port nn reaches the provisioned setpoint (VOA Power Ref).
Step 24 Display the west 32DMX-O in card view.
Step 25 Click the Provisioning > Optical Chn > Parameters tabs.
Step 26 Change the Admin State of Port nn to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 27 Check that the power value on Port nn reaches the provisioned setpoint (VOA Power Ref).
Step 28 (Optional) Connect a power meter to the CHAN TX nn port through the patch panel and verify that the
physical optical power coming out of drop Port nn on the west 32DMX-O is consistent with the value
read on the meter within 0.5 dB.
Step 29 Repeat Steps 18 through 28 for the remaining wavelengths on the 100-GHz grid that are not pass-through
wavelengths.
Step 30 Remove the loopback connection on the west OPT-BST.
Step 31 Complete the “NTP-G37 Run Automatic Node Setup” procedure on page 3-83 to restore the original
configuration.
Step 32 Create a loopback on the east OPT-BST amplifier by connecting a patchcord from the LINE TX port to
the LINE RX port with 10-dB bulk attenuator.
Step 33 Verify that the OSC link becomes active on the east OSCM card. (The OSC termination must be already
provisioned. If not, complete the “NTP-G38 Provision OSC Terminations” procedure on page 3-84.)
Step 34 Repeat 18 through 33 for the east side cards.
Step 35 Remove the loopback on the east OPT-BST.
Step 36 Restore the default administrative state (IS,AINS/Unlocked,automaticInService) on all the ports
previously set to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Stop. You have completed this procedure.