RUGGEDCOM ROX II
CLI User Guide
Chapter 2
Using RUGGEDCOM ROX II
Using Output Redirects 31
Parameter Description
lm4 E1 w/ 2x BNC - -
lm5 none - -
lm6 none - -
power-controller
PM MOV PM PM PM
SLOT PROTECTION TEMPERATURE CURRENT VOLTAGE
------------------------------------------------
pm1 na 43 2907 3381
For example, show chassis | begin line-modules | notab suppresses the table formatting:
ruggedcom# show chassis | begin line-modules | notab
line-modules
line-module lm1
detected module "1000TX w/ 2x RJ45"
line-module lm2
detected module none
line-module lm3
detected module "6x RS232/RS422/RS485 via RJ45"
line-module lm4
detected module "E1 w/ 2x BNC"
line-module lm5
detected module none
line-module lm6
detected module none
power-controller
PM MOV PM PM PM
SLOT PROTECTION TEMPERATURE CURRENT VOLTAGE
------------------------------------------------
pm1 na 43 2892 3381
repeat Repeats the term at the specified interval. Specify an interval in seconds. The term repeats
until you cancel it with Ctrl-C.
For example, show admin | repeat 10s repeats the show admin term every 10 seconds.
save Saves the output to the specified ASCII text file.
For example, show chassis | save foo.txt saves the chassis information to the file foo.txt
select This redirect is not yet implemented.
tab Enforces table layout for columnar data.
until Includes output until a line containing the specified text appears. Regular expressions
can be used with this redirect. For more information about regular expressions, refer to
Section2.5.7, “Using Regular Expressions”.
For example, show chassis | begin cpu | until status returns the chassis information
beginning with cpu and ending with status:
ruggedcom# show chassis | begin cpu | until status
cpu
slot-cpu main
detected module "RX1501 8 Gigabit Layer 3 w/ 6 LM slots and 1 PM
slots"
cpu load 22
ram avail 53
ram avail low 20
status

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROX II and is the answer not in the manual?

Siemens RUGGEDCOM ROX II Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROX II
CategoryNetwork Hardware
LanguageEnglish

Related product manuals