Other Troubleshooting
When Fluorescent/ LED Lamps Flicker
Problem
Under the usage environment of this machine, at the placement location, fluorescent and/or LED
lamps flicker.
Causes
As a result of the voltage drop occurs, when the fusing lamp is applied an electrical current. It
depends on the electrical power environment, at the customer's placement location.
Solutions
The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the
procedure that matches the timing.
Occurrence Timing
Timing Solutions Side effect
Recovery from
energy saving
Set SP1-135-001 (Inrush
Control) to "1 (ON)".
Recovery time from energy saving
becomes slower approx. 0.4 sec..