Loading...
Thin
Paper
Plain
Paper
1
Plain
Paper
2
Middle
Thick
Thick
Paper
1
Thick
Paper
2
Thick
Paper
3
Thick
Paper
4
Special Paper 2 - - - - -
Special Paper 3 - - - - -
Letterhead - - - - -
Preprinted Paper - - - - -
Bond Paper - - - - -
Cardstock - - - - -
OHP
(Transparency)
- - - - - - - -
Label Paper - - - - -
Coated: Matte - - - - - - - -
Envelope - - - - - - - -
Coated: Glossy - - - - - - - -
SP1-907-096 (Operation Setting: Fusing Exit SOL Setting)
By changing SP1-907-096, the curl correction mechanism can be enabled regardless of the paper
setting.
If the fusing exit drive solenoid is ON, the curl correction function is OFF.
If the fusing exit drive solenoid is OFF, the curl correction function is ON.
SP value
Curl Correction
Tray Bypass
0 Normal Operation
1 Normal Operation Always OFF
2 Always OFF Normal Operation
3 Always OFF Always OFF
4 Normal Operation Always ON
Fusing
1197