Verification of Up Time for each Energy Saving State
The up time for each power state of the machine can be checked with SP8-961 (Electricity Status). It is
also output on the SMC sheet.
SP Name Description
SP8-961-001 Ctrl Standby Time Cumulative time of Engine OFF mode, Quiet mode,
and Standby mode
SP8-961-002 STR Time Cumulative time of STR mode
SP8-961-003 Main Power Off Time Cumulative time of state in which the power plug is
connected to the outlet but the main power is off
SP8-961-004 Reading and Printing Time Cumulative time of state in which both the plotter
engine and scanner engine are running or warming
up
SP8-961-005 Printing Time Cumulative time of the state in which the plotter
engine is running
SP8-961-006 Reading Time Cumulative time of the state in which the scanner
engine is running
SP8-961-007 Eng Waiting Time Cumulative time of state in which the power state of
the engine is Standby state
SP8-961-008 Low Power State Time Not used for this machine
SP8-961-009 Quiet State Time Cumulative time of the state in which the power state
of the engine is Quiet state
SP8-961-010 Heater Off State Time Cumulative time of the state in which the power state
of the engine is fusing OFF state
SP8-961-011 LCD on Time Cumulative time of the state in which the backlight of
the LCD is on.
Checking the Up Time by Device State
SP8-941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.