Value Meaning Solution/ Workaround
9 Request number confirmation executing Processing… Please wait.
11 Already registered -
12 Parameter error -
20 Dial-up authentication error
* These errors occur only in the modems
that support @Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 unplugged modem
26 Busy line
8. Exit the SP mode.
SP5-816-208 Error Codes
Caused by Operation Error, Incorrect Setting
Code Meaning Solution/ Workaround
-12002
Inquiry, registration attempted without
acquiring Request No.
Obtain a Request Number before
attempting the Inquiry or Registration.
-12003
Attempted registration without execution of a
confirmation and no previous registration.
Perform Confirmation before attempting
the Registration.
-12004
Attempted setting with illegal entries for
certification and ID2.
Check ID2 of the mainframe.
-12005
@Remote communication is prohibited. The
device has an Embedded RC gate-related
problem.
Make sure that "Remote Service" in User
Tools is set to "Do not prohibit".
-12006
A confirmation request was made after the
confirmation had been already completed.
Execute registration.
-12007
The request number used at registration was
different from the one used at confirmation.
Check Request No.
2. Installation