Value Meaning Solution/ Workaround
6 Communication error Check the network condition.
8 Other error
See "SP5816-208 Error Codes" below
this.
9 Request number confirmation executing Processing… Please wait.
11 Already registered -
12 Parameter error -
20 Dial-up authentication error
* These errors occur only in the modems
that support @Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 unplugged modem
26 Busy line
5. Make sure that the screen displays the Location Information with SP5-816-205 only when
it has been input at the Center GUI.
6. Click [EXECUTE] to execute the registration with SP5-816-206.
7. Check the registration result with SP5-816-207.
Value Meaning Solution/ Workaround
0 Succeeded -
1 Request number error Check the request number again.
2 Already registered Check the registration status.
3 Communication error (proxy enabled) Check the network condition.
4 Communication error (proxy disabled) Check the network condition.
5 Proxy error (Authentication error) Check Proxy user name and password.
8 Other error
See "SP5-816-208 Error Codes" below
this.