Scanner Features
Display Settings of Recently Used Scan Destination
Configuring the scanner interface so that the most recently used scan destination is cleared.
Whether the MFP clears the most recently used scan destination, can be configured using Scanner SP
1-012-001.
By default, this is cleared to avoid subsequent users scanning to it by mistake.
Scanner SP 1-012-001
1 (default): Clear
0: Do not clear
This will cause all of the following to be cleared after the scanning is complete:
• Destination
• Sender
• Email subject
• Email message
• File name
Scanner SP 1-012-001=1 (default):
Exceptions:
• User Auth.:
If SP 1-012-001 = 0 and if User Auth. (excluding User Code authentication) is enabled, the most
recently used scan destination will only be retained until the user logs out.
• Scanner Auto Reset timer:
5. Software Configuration
684