Fusing Temperature Control
Warm-up mode
After power ON, fusing warm-up begins. The fusing motor is switched ON, the halogen lamp is
energized, and the fusing temperature is increased to the "reload target temperature."
When fusing warm-up is completed, the fusing motor stays ON for a certain time, and the fusing
temperature is maintained at the "reload target temperature."
Standby mode
After fusing reload, when a certain time has elapsed, power supply to the halogen lamp is
switched OFF, and the fusing motor is switched OFF. At the same time, the temperature is
maintained at the "standby target temperature (SP1-107-001)" by the halogen lamp.
In standby mode, the Fusing motor rotates once every 60 minutes.
The operation interval of the Fusing motor can be changed by SP1-122-001 (Standby Rotation
Setting Rotation Interval) but the change may cause the uneven glossiness on the image.
7. Detailed Descriptions
1192