SC No. Type Error Name/Error Condition/Major Cause/Solution
SC900-00 A Electric counter error
The electric total counter value is out of specification.
Error is detected when increasing the total counter.
Unexpected NV-RAM is attached.
NV-RAM defective
NV-RAM data corrupted.
Data written to unexpected area because of external factor etc.
The count requested by the SRM on receiving PRT is not completed.
Replace the NV-RAM.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC910-01 C External controller error 1
SC910-02 C External controller error 2
SC910-03 C External controller error 3
-01
The external controller receives the unexpected command from the
engine side.
-02
The external controller wrongly receives the command from the engine
side.
-03
The external controller receives the engine status out of specification.
Refer to the instructions for the external controller
Turn the main power OFF/ON.