EasyManuals Logo

Ricoh MP C2504 User Manual

Ricoh MP C2504
1923 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1132 background imageLoading...
Page #1132 background image
The Process Control Procedure
The potential of the unexposed drum is called the electrified potential (Vd), whereas the potential when
toner starts to adhere to the drum is called the development bias (Vb).
Toner starts to adhere to the drum in proportion to the potential when the value of potential becomes
more than Vb. The value (coefficient) which shows the relation between the potential and the amount of
adhesion is called development gamma.
In addition to the development gamma and the potential, the toner density in the developer needs to be
controlled. This is done to maintain the proper toner density (the amount of toner adhesion).
The target figure for the toner density in the developer is called Vref.
Process control is done as shown in the following chart, which includes development gamma
determination, Vref correction, and LD power control.
Process Control
1123

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP C2504 and is the answer not in the manual?

Ricoh MP C2504 Specifications

General IconGeneral
Print TechnologyLaser
FunctionsPrint, Copy, Scan, Fax
Print Resolution1200 x 1200 dpi
Scan TypeFlatbed, ADF
Max Scan Resolution600 x 600 dpi
Copy Resolution600 x 600 dpi
Max Paper SizeA3
Duplex PrintingYes
Memory (RAM)2 GB
Print Speed25 ppm (A4)
Copy Speed25 cpm (A4)
Fax Resolution200 x 200 dpi
Paper Capacity1200 sheets
ConnectivityUSB, Ethernet, Wi-Fi
Dimensions587 x 685 x 913 mm
Control Panel9-inch Smart Operation Panel

Related product manuals