Category Code Result name Description
45 and larger
ID Pattern detection
45 ID Pattern extract error Cannot detect ID Pattern
50 Vmin_Bk/K2 error (Max) K:Vmin_Bk / CMY:K2 > Max
51 Vmin_Bk/K2 error (Min) K:Vmin_Bk / CMY:K2 < Min
52 K5 error (Max) K5 > Max
53 K5 error (Min) K5 < Min
54
K5 calculated approximate
point error
K5 calculated approximate point <
Min
55
Development gamma error
(Max)
Development gamma > Max
56
Development gamma error
(Min)
Development gamma < Min
57
Start developing voltage: Vk
error(Max)
Start developing voltage: Vk > Max
58
Start developing voltage: Vk
error(Min)
Start developing voltage: Vk < Min
59 Not enough valid data
Adhesion amount data for
development gamma calculation
point is under 2.
90 and larger
Result(End)
90 Potential not adjusted
Potential control method is set as
[0:FIX].
99 Stopped
Stopped by door open, power off,
error. (Set when execute.)
• Execution result example (In order of YMCK from left)
• Factory default (SP default): [00,00,00,00]
• Starting adjust: [99,99,99,99]
• Fail Vsg adjust(Y): [21,99,99,99]
• Error of Development gamma Max(C): [99,99,55,99]
• Succeeded: [11,11,11,11]
7. Detailed Descriptions