SP3-102-011 to 014 (Toner Remain:Disp: Pixel Bk, C, M, Y)
Displays the remaining toner calculated from imaging size.
SP3-102-021 to 024 (Toner Remaining: Display: Fill Amount Bk, C, M, Y)
Display the filler content of new bottle.
SP3-120-001 to 004 (TE Sn Detect Thresh: Bk, C, M, Y)
Sets the starting threshold of the near-toner end detection by the toner end sensor.
SP3-121-001 to 004 (TE Counter: Disp: Bk, C, M, Y)
Displays the number of times the toner end sensor detected toner end.
SP3-122-001 to 004 (TE Sn NE Thresh: Bk, C, M, Y)
Sets the number of toner end detection to start near-toner end detection.
SP3-163-001 (Bottle Drive: Set Rotation Time at Toner End)
Sets the empty turn time[ms] at almost toner-end.
SP3-133-011 to 014 (TE Detect :Set Page Cnt:K, C, M, Y)
Displays the amount of sheets printed after toner near end is fixed.
SP3-133-031 to 034 (TE Detect :Set Pxl Cnt:K, C, M, Y)
Displays the amount of toner used in cm2 after toner near-end is fixed.
SP3-210-001 to 004 (TD.Sens:Vt :Disp: Current: K, C, M, Y)
Displays the latest TD sensor output.
SP3-131-001 (Vt TE Thresh: Delta Vt Thresh)
Specifies the threshold to start adding the delta Vt after toner Near End.
SP3-132-001 to 004 (Delta Vt Sum: Bk, C, M, Y)
Displays the integrated value of delta Vt.
SP3-131-011 (Delta Vt Thresh BF NE)
Specifies the threshold to start integrating delta Vt before toner Near End.
SP3-131-012 (Delta Vt Sum Thresh BF NE)
Specifies the threshold of delta Vt to check Toner End before toner Near End.