Item
PM
Parts
Cycle EM Remarks
PCU(K)
R
60K
-
PCU(C,M,Y) -
R
48K
-
Development unit (K)
R
180K
- PM parts: only for MP C2504
Development unit (C,M,Y) -
R
120K
-
Waste toner bottle
R
100K
-
Target yield (number of sheets) is only
a guide and it is possible to collect up
to 1,200,000 mg of waste toner. Full
detection is a mechanical detection by
a feeler. Replace when waste toner
bottle full is detected.
Transfer
Image transfer cleaning unit -
R
240K
-
Image transfer belt unit -
R
240K
-
Paper transfer roller unit -
R
240K
-
Fusing
Fusing sleeve belt unit -
R
240K
-
Fusing entrance guide plate - - C Remove toner deposits
Fusing exit guide plate - - C Remove toner deposits
Stripper plate - - C Remove toner deposits
2. Preventive Maintenance