1-101-015 Forced Reload Time:Hot *ENG [0 to 100 / 15 / 0.1sec/step]
1-101-016 Temp.:Delta:Cold:BW1/2:Cent
er
*ENG [4 to 200 / * / 1deg/step]
*NA: 42, EU: 46, Asia: 46, CHN: 46,
TWN: 42, KOR: 46
1-101-017 Temp.:Delta:Cold:BW1/2:End *ENG [4 to 200 / * / 1deg/step]
*NA: 42, EU: 46, Asia: 46, CHN: 46,
TWN: 42, KOR: 46
1-101-018 Temp.:Delta:Cold:BW1/2:Pres
s
*ENG [4 to 200 / 110 / 1deg/step]
1-101-019 Forced Reload
Time:Cold:BW1/2
*ENG [0 to 100 / 15 / 0.1sec/step]
1-101-101 Reload Target
Temp.:Center:Energy Saving
*ENG [0 to 200 / * / 1deg/step]
*NA: 116, EU: 114, Asia: 114, CHN:
114, TWN: 116, KOR: 114
1-101-102 Reload Target
Temp.:Press:Energy Saving
*ENG [0 to 200 / 120 / 1deg/step]
1-101-103 Temp.:Delta:Cold:Energy
Saving:Center
*ENG [0 to 200 / * / 1deg/step]
*NA: 34, EU: 42, Asia: 42, CHN: 42,
TWN: 34, KOR: 42
1-101-104 Temp.:Delta:Cold:Energy
Saving:End
*ENG [0 to 200 / * / 1deg/step]
*NA: 34, EU: 42, Asia: 42, CHN: 42,
TWN: 34, KOR: 42
1-101-105 Temp.:Delta:Cold:Energy
Saving:Press
*ENG [4 to 200 / 100 / 1deg/step]
1-101-106 Forced Reload
Time:Cold:Energy Saving
*ENG [0 to 100 / 30 / 0.1sec/step]
1-101-151 Temp.:Delta:Low Temp.:Center *ENG [4 to 200 / 6 / 1deg/step]
1-101-152 Temp.:Delta:Low Temp.:End *ENG [4 to 200 / 6 / 1deg/step]
1-101-153 Temp.:Delta:Low Temp.:Press *ENG [4 to 200 / 70 / 1deg/step]
1-101-154 Forced Reload Time:Low Temp. *ENG [0 to 100 / 35 / 0.1sec/step]