1-951-007 Paper Exit Cooling Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-011 PSU Cooling Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-051 Dev Suction Fan: Right *ENG [0 to 900 / 0 / 1sec/step]
1952 [Fan Control Off Mode Time Set]
1-952-001 - *ENG [0 to 60 / 10 / 1min/step]
1953 [Extra Fan Control]
1-953-001 Extra Fan Cooling State *ENG [0 or 1 / 0 / 1/step]
0: Disable
1: enable
1-953-002 Execution Temp. Threshold *ENG [0 to 100 / 38.5 / 0.1deg/step]
1-953-003 Cancellation Temp. Threshold *ENG [0 to 100 / 2 / 0.1deg/step]
1-953-004 Extra Fan Operation ON/OFF
Setting
*ENG [0 or 1 / 1 / 1/step]
0: disable
1: enable
1955 [Fan Control]
1-955-004 Dev Cooling Fan Op Sw Temp *ENG [0 to 100 / 36 / 0.1deg/step]
1-955-006 Paper Exit Cooling Fan Op Sw
Temp
*ENG [0 to 100 / 12 / 0.1deg/step]
1-955-007 Fusing Fan Op Sw Temp *ENG [0 to 100 / 0 / 0.1deg/step]
1-955-009 Ozone Fan Low Speed Op Sw
Temp
*ENG [0 to 100 / 35 / 0.1deg/step]
1-955-010 Ozone Fan Middle Speed Op
Sw Temp
*ENG [0 to 100 / 37 / 0.1deg/step]
1-955-011 Ozone Fan High Speed Op Sw
Temp
*ENG [0 to 100 / 40 / 0.1deg/step]
1-955-012 Ozone Fan Low Noise Op
DUTY
*ENG [0 to 100 / 20 / 1%/step]
Engine SP Tables - SP1000-2
155