2-241-004 AIT Temperature ENG [0 to 70 / 0 / 0.1deg/step]
2242 [TS Operation Env. Log]
2-242-001 TS<=A-3 ENG [0 to 99999999 / 0 / 1mm/step]
2-242-002 A-3<TS<=A ENG [0 to 99999999 / 0 / 1mm/step]
2-242-003 A<TS<=A+3 ENG [0 to 99999999 / 0 / 1mm/step]
2-242-004 A+3<TS ENG [0 to 99999999 / 0 / 1mm/step]
2-242-100 Log Clear ENG [0 or 1 / 0 / 1/step]
2250 [Interval Downmode]
2-250-001 ON/OFF Setting ENG [0 or 1 / 1 / 1/step]
2302 [Environmental Correction:Trans]
2-302-001 Current Environmental Display ENG [0 to 0 / 0 / 0/step]
2-302-002 Forced Setting *ENG [0 to 6 / 0 / 1/step]
0: Sensor detect
1: LL
2: ML
3: MM
4: HM
5: HH
6: SLL
2-302-003 Absolute Humidity:Threshold 1 *ENG [0 to 100 / 4 / 0.01g/m
3
/step]
2-302-004 Absolute Humidity:Threshold 2 *ENG [0 to 100 / 8 / 0.01g/m
3
/step]
2-302-005 Absolute Humidity:Threshold 3 *ENG [0 to 100 / 16 / 0.01g/m
3
/step]
2-302-006 Absolute Humidity:Threshold 4 *ENG [0 to 100 / 24 / 0.01g/m
3
/step]
2-302-007 Temperature:Threshold *ENG [-5 to 30 / 5 / 1deg/step]
2303 [Time-Lapse Correction]
Engine SP Tables - SP2000-1
191