Category Code Result name Description
40 and larger
ID Sensor
41 ID sensor output error (Max) Vt > Max
42 ID sensor output error (Min) Vt < Min
43 ID Sensor error (Max)
Development gamma is in target,
but Vt value is less than upper limit.
44 ID Sensor error (Min)
Development gamma is in target,
but Vt value is less than lower limit.
45 and larger
ID Pattern detection
45 ID Pattern extract error Cannot detect ID Pattern
50 Vmin_Bk/K2 error (Max) K:Vmin_Bk / CMY:K2 > Max
51 Vmin_Bk/K2 error (Min) K:Vmin_Bk / CMY:K2 < Min
52 K5 error (Max) K5 > Max
53 K5 error (Min) K5 < Min
54
K5 calculated approximate point
error
K5 calculated approximate point <
Min
55
Development gamma error
(Max)
Development gamma > Max
56 Development gamma error (Min) Development gamma < Min
57
Start developing voltage: Vk
error(Max)
Start developing voltage: Vk >
Max
58
Start developing voltage: Vk
error(Min)
Start developing voltage: Vk < Min
59 Not enough valid data
Adhesion amount data for
development gamma calculation
point is under 2
90 and larger
Result(End)
90 Potential not adjusted
Potential control method is set as
[0:FIX]
99 Stopped
Stopped by door open, power off,
error.
(Set when execute.)