3-531-003 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
3-531-004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m
3
/step]
3-531-005 Maximum Execution Number *ENG [0 to 99 / 10 / 1count/step]
3532 [Prediction Control :Set]
3-532-001 Prediction ControlON/OFF *ENG [0 to 1 / 0 / 1/step]
3533 [Interrupt ProCon :Set]
3-533-001 Interval:Set:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-533-002 Interval:Disp:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-533-003 Corr(Short):BW *ENG [0 to 1 / 1 / 0.01/step]
3-533-004 Corr(Mid):BW *ENG [0 to 1 / 1 / 0.01/step]
3-533-011 Interval:Set:FC *ENG [0 to 5000 / 200 / 1sheet/step]
3-533-012 Interval:Disp:FC *ENG [0 to 5000 / 200 / 1sheet/step]
3-533-013 Corr(Short):FC *ENG [0 to 1 / 1 / 0.01/step]
3-533-014 Corr(Mid):FC *ENG [0 to 1 / 1 / 0.01/step]
3534 [JobEnd ProCon :Set]
3-534-001 Interval:Set:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-534-002 Interval:Disp:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-534-003 Corr(Short):BW *ENG [0 to 1 / 1 / 0.01/step]
3-534-004 Corr(Mid):BW *ENG [0 to 1 / 1 / 0.01/step]
3-534-011 Interval:Set:FC *ENG [0 to 1000 / 200 / 1sheet/step]
3-534-012 Interval:Disp:FC *ENG [0 to 5000 / 200 / 1sheet/step]
3-534-013 Corr(Short):FC *ENG [0 to 1 / 1 / 0.01/step]
3-534-014 Corr(Mid):FC *ENG [0 to 1 / 1 / 0.01/step]