5-803-037 Toner End Sensor:K ENG [0 or 1 / 0 / 1/step]
0: End
1: Not End
Detects remaining toner amount.
*Power with SP5-804-172 before checking.
(0: End, 1: Not End)
5-803-038 Fusing:Area Detection ENG [0 to 15 / 0 / 1/step]
01:200V system
10:100V System
00, 01:unit set error
Detects region of fusing unit.
(0111: 200V system, 1011: 100V System)
5-803-039 Fusing:New Unit Detection ENG [0 or 1 / 0 / 1/step]
0: New
1: Old
Detects New/Old of fusing unit.
(0: New, 1: Old)
5-803-040 Fusing Temp Detect ENG [0 or 1 / 0 / 1/step]
0: Normal
1: High temperature
Detects whether high temperature is detected from fusing unit.
(0: Normal, 1: High temperature)
5-803-041 NC Sensor Temp Detection/ 2 ENG [0 or 1 / 0 / 1/step]
0: Normal
1: High temperature
Detects whether high temperature is detected from fusing unit.
(0: Normal, 1: High temperature)
Input and Output Check
455