5-307-003 Rule Set (Start) *CTL [0 to 0xffffffff / - / 1hex]
(Default)
NA: 0x11100200
EUR: 0x10500100
ASIA: 0x03100000
Other: 0x00000000
Specifies the start setting for the summer time mode.
There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the first digit,
so the eight-digit setting for -2 or -3 becomes a seven-digit setting.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour ]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes ]
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
5-307-004 Rule Set (End) *CTL [0 to 0xffffffff / - / 1hex]
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
5401 [Access Control]
5-401-103 Default Document ACL CTL [0 to 3 / 0 / 1]
5-401-104 Authentication Time CTL [0 to 255 / 0 / 1sec/step]
Controller SP Tables - SP5000