5413 [Lockout Setting]
5-413-001 Lockout On/Off *CTL [0 or 1 / 0 / 1]
0: Off
1: On
5-413-002 Lockout Threshold *CTL [1 to 10 / 5 / 1]
5-413-003 Cancellation On/Off *CTL [0 or 1 / 0 / 1]
0: Off (no wait time, lockout not
cancelled)
1: On (system waits, cancels lockout if
correct user ID and password are
entered.
5-413-004 Cancellation Time *CTL [1 to 9999 / 60 / 1min]
5414 [Access Mitigation]
5-414-001 Mitigation On/Off *CTL [0 or 1 / 0 / 1]
0: OFF
1: ON
5-414-002 Mitigation Time *CTL [0 to 60 / 15 / 1min/step]
5415 [Password Attack]
5-415-001 Permissible Number *CTL [0 to 100 / 30 /1attempt/step]
5-415-002 Detect Time *CTL [1 to 10 / 5 / 1sec/step]
5416 [Access Information]
5-416-001 Access User Max Num *CTL [50 to 200 / 200 / 1user/step]
5-416-002 Access Password Max Num *CTL [50 to 200 / 200 / 1password/step]
5-416-003 Monitor Interval *CTL [1 to 10 / 3 / 1sec/step]
5417 [Access Attack]
5-417-001 Access Permissible Number *CTL [0 to 500 / 100 / 1/step]