5-507-133 Interval :A4 *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-134 Interval :A5 *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-141 Interval :B4 *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-142 Interval :B5 *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-160 Interval :DLT *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-164 Interval: LG *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-166 Interval :LT *CTL [250 to 10000 / 1000 / 1page/
step]
5-507-172 Interval :HLT *CTL [250 to 10000 / 1000 / 1page/
step]
5508 [CC Call]
5-508-001 Jam Remains *CTL [0 or 1 / 1 / 1]
0: Disable
1: Enable
5-508-002 Continuous Jams *CTL [0 or 1 / 1 / 1]
0: Disable
1: Enable
5-508-003 Continuous Door Open *CTL [0 or 1 / 1 / 1]
0: Disable
1: Enable
5-508-011 Jam Detection: Time Length *CTL [3 to 30 / 10 / 1min/step]
5-508-012 Jam Detection: Continuous
Count
*CTL [2 to 10 / 5 / 1time/step]
5-508-013 Door Open: Time Length *CTL [3 to 30 / 10 / 1min/step]
Controller SP Tables - SP5000
519