5-816-002 CE Call *CTL [0 or 1 / 0 / 1]
0: Start of the service
1: End of the service
5-816-003 Function Flag *CTL [0 or 1 / 0 / 1]
0: Disabled
1: Enabled
5-816-007 SSL Disable *CTL [0 or 1 / 0 / 1]
0: Yes. SSL not used.
1: No. SSL used.
5-816-008 RCG Connect Timeout *CTL [1 to 90 / 30 / 1second/step]
5-816-009 RCG Write Timeout *CTL [0 to 100 / 60 / 1second/step]
5-816-010 RCG Read Timeout *CTL [0 to 100 / 60 / 1second/step]
5-816-011 Port 80 Enable *CTL [0 or 1 / 0 / 1]
0: No. Access denied
1: Yes. Access granted.
5-816-013 RFU Timing *CTL [0 or 1 / 1 / 1]
0: Any status of a target machine
1: Sleep or panel off mode only
5-816-014 RCG Error Cause CTL [0 or 1 / 0 / 1]
0: Initial state, normal condition
1: Error
5-816-021 RCG – C Registed *CTL [0 or 1 / 0 / 1]
0: Installation not completed
1: Installation completed
5-816-023 connect type(N/M) *CTL [0 or 1 / 0 / 1]
0: internet connection
1: Dial-up connection
5-816-061 Cert Expire Timing *CTL [0 to 0xffffffff / 0 / 1]
0: Not use
1: Use