Bit Item 0 1 Description
Initial
value
1
Access
Permission
Enabled Disabled
Setting this value to “0” permits only
internal access in the machine (MFP
browser).
Setting this value to “1” permits to
access from external devices such as
PC, Remote UI, IT-BOX.
0
2
Select IPv6/
IPv4
IPv6 IPv4
Setting this value to “0” permits only
accessing with IPv6.
Setting this value to “1” permits
accessing with IPv4 or IPv6.
0
3 Remote UI Not use Use Sets whether to use the Remote UI. 0
4 Reserved - - N/A N/A
5 Reserved - - N/A N/A
6 Reserved - - N/A N/A
7 Reserved - - N/A N/A
• SP5-985-001/002 (Device Setting: On Board NIC/On Board USB)
The NIC and USB support features are built into the GW controller. Use this SP to enable and
disable these features. In order to use the NIC and USB functions built into the controller board,
these SP codes must be set to "1".
• SP5-824-001 (NV-RAM Data Upload)
Uploads the NVRAM data to an SD card.
• SP5-825-001 (NV-RAM Data Download)
Downloads data from an SD card to the NVRAM in the machine.
• SP5-755-002 (Hide Administrator Password Change Scrn)
Hides the input screen of the administrator password temporarily.
• SP5-193-001 (External Controller Info. Settings)
Sets the model of the external controller connected to the main unit.
0: External Controller is not installed
1: EFI
2: Ratio
3: Egret
4. Replacement and Adjustment
612