SC No. Type Error Name/Error Condition/Major Cause/Solution
SC142-00 D White level detection error
The white level cannot be adjusted to the second target level within the
target during auto gain control.
• Scanner Carriage defective
• IPU defective
• Harness defective
• Connector defective (disconnected, loose)
• Condensation in scanner unit
• White plate dirty or installed incorrectly
Check if the SC occurs by turning the power OFF then ON. If the SC
occurs again, do the following steps. Check if the SC reoccurs by cycling
the power after each step.
1. Reconnect the following connectors;
• Scanner Carriage - IPU harness (FFC)
• SBU - LEDB harness (FFC)
• IPU- BCU harness
2. Check the white reference seal that attached back of sheet-through
exposure glass. Replace the sheet-through exposure glass, if dirty or
damaged.
3. Replace the scanner carriage.
4. Replace the IPU.
5. Replace the following harnesses;
• Scanner Carriage - IPU harness (FFC)
• IPU - BCU harness
6. Replace the BCU.
Service Call 101-195
777