SC No. Type Error Name/Error Condition/Major Cause/Solution
SC151-00 D Black Level Error: Side 2
The black level scanned is not specified range.
CIS for SPDF defective
SPDF main board defective
Harness defective
Check if the SC occurs by turning the power OFF then ON. If the SC
occurs again, do the following steps. Check if the SC reoccurs by cycling
the power after each step.
1. Reconnect the SPDF main board - CIS connectors if they are
disconnected, or loose.
2. Replace the CIS for SPDF
3. Replace the following harnesses;
SPDF main board - CIS
IPU -SPDF main board
4. Replace the SPDF main board.
Service Call 101-195
779