SC No. Type Error Name/Error Condition/Major Cause/Solution
SC665-07 D IPU signal Communication Error
The machine detects the communication error between CPU and Slave
device when starting up, or recovery from energy saver mode.
FFC connection error
FFC defective (disconnected, foreign object, etc.)
The following board defects (Parts implementation defect, solder
scrap, implemented parts defect, etc.);
BCU
IPU
1. Turn the main power OFF/ON.
2. Reconnect the following FFC;
BCU - Imagine IOB
Imaging IOB - Paper Transport IOB
3. Replace the following FFC;
BCU - Imagine IOB
Imaging IOB - Paper Transport IOB
4. Replace the BCU.
5. Replace the IPU.
Service Call 620-687