SC No. Type Error Name/Error Condition/Major Cause/Solution
SC668-02 D Vodka2 Version Setting Error
The machine detects the version settings error in Vodka2 when starting
up, or recovery from energy saver mode.
The following board defects (Parts implementation defect, solder scrap,
implemented parts defect, etc.);
• BCU
• Imaging IOB
1. Turn the main power OFF/ON.
2. Replace the Imaging IOB.
3. Replace the BCU.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC668-03 D Vodka1,2 Version Setting Error
The machine detects the version settings error in both Vodka 1 and
Vodka2 when starting up, or recovery from energy saver mode.
The following board defects (Parts implementation defect, solder scrap,
implemented parts defect, etc.);
• BCU
• Imaging IOB
• Paper Transport IOB
1. Turn the main power OFF/ON.
2. Replace the BCU.
3. Replace the Imaging IOB.
4. Replace the Paper Transport IOB.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC669-** EEPROM Communication Error
SC669-01 D EEPROM OPEN: ID error
SC669-02 D EEPROM OPEN: Channel error
Service Call 620-687