EasyManua.ls Logo

Ricoh MP C2504 - Page 895

Ricoh MP C2504
1923 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-03 D IPU start up error when the machine boots up
VDET_EPCI signal was not asserted when the machine was turned on.
• IPU, PSU, and/or CTL defective
• Incorrect connection between CTL and IPU.
• Harness of IPU disconnected
Refer to page 977 "When SC670 (Engine start up error) is displayed".
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-04 D Communication error between the engine and controller
Communication could not linked up.
• IPU and/or CTL defective
• Incorrect connection between CTL and IPU.
Refer to page 977 "When SC670 (Engine start up error) is displayed".
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-10 D Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established.
• Controller stalled
• Board installed incorrectly
• Controller board defective
• Operation panel connector loose, broken, or defective
• Controller late
Refer to page 978 "When SC672 (Controller start up error) Is
Displayed".
6. Troubleshooting
886
SC672
RTB 34

Table of Contents