SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-03 D IPU start up error when the machine boots up
VDET_EPCI signal was not asserted when the machine was turned on.
IPU, PSU, and/or CTL defective
Incorrect connection between CTL and IPU.
Harness of IPU disconnected
Refer to page 977 "When SC670 (Engine start up error) is displayed".
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-04 D Communication error between the engine and controller
Communication could not linked up.
IPU and/or CTL defective
Incorrect connection between CTL and IPU.
Refer to page 977 "When SC670 (Engine start up error) is displayed".
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-10 D Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Refer to page 978 "When SC672 (Controller start up error) Is
Displayed".
6. Troubleshooting
886
SC672
RTB 34

Table of Contents