SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-13 D Controller start up error
The operation panel detects that the controller is down due to other
reason shown in SC672-10, SC672-11, and SC672-12.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Refer to page 978 "When SC672 (Controller start up error) Is
Displayed".
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-99 D Controller start up error
The operation panel software ended abnormally.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Refer to page 978 "When SC672 (Controller start up error) Is
Displayed".
6. Troubleshooting
888