No. Type Error Name/Error Condition/Major Cause/Solution
SC823-00 B Self-diagnostics error: NIC
[XXXX]: Detailed error code
[6101] MAC address check sum error
The result of the MAC address check sum does not match the check sum
stored in ROM.
Defective SEEP ROM
Defective I2C bus (connection)
Replace the controller board.
[6104] PHY IC error
The PHY IC on the controller cannot be correctly recognized.
Defective PHY chip
Defective ASIC MII I/F
Replace the controller board.
[6105] PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the
controller.
PHY chip
Defective MAC of ASIC (SIMAC/COMIC/CELLO)
Defective I/F with the PHY board
Defective solder on the PHY board
Replace the controller board.