No. Type Error Name/Error Condition/Major Cause/Solution
SC857-00 B USB I/F Error
The USB interface is unusable because of a driver error.
USB driver error (There are three causes of USB error: RX error/CRC
error/STALL. SC is issued only in the case of STALL.)
Check USB connection.
Replace the controller board.
No. Type Error Name/Error Condition/Major Cause/Solution
SC858-00 A Data encryption conversion error (Key Setting Error)
A serious error occurred during an attempt to update the encryption key.
USB Flash, other data, corrupted
Communication error caused by electrostatic noise
Controller board defective
Replace the controller board.
No. Type Error Name/Error Condition/Major Cause/Solution
SC858-01 A Data encryption conversion error (HDD Key Setting Error)
A serious error occurred during an attempt to update the encryption key.
USB Flash, other data, corrupted
Communication error caused by electrostatic noise
Controller board defective
Turn the main power OFF/ON.
If the error persists, replace the controller board.
Service Call 816-899
933