No. Type Error Name/Error Condition/Major Cause/Solution
SC869-01 C Continuously detecting malfunction
The proximity sensor (human detection sensor) keeps in a detection state
and accumulated time exceeds 24 hours.
The proximity sensor (human detection sensor) is disabled and is in the
detection state at all times.
SC869-02 C Continuously non-detecting malfunction
In the non-detection state, the following operations are detected 20 times
continuously.
• Pressing "energy saver" key or touching the operation panel
• Opening/closing the plate cover or ADF
• Setting the original
• Opening the front cover
• Opening the paper feed tray
The proximity sensor (human detection sensor) is disabled and is in the
non-detection state at all times.
Service Call 816-899
945