To clear SC544-02 or SC554-02, replacing the fusing unit or installing an intact new unit detection fuse
in the fusing unit must be required. The intact new unit detection fuse is provided in the fusing sleeve belt
unit.
When replacing the fusing sleeve belt unit, follow the procedure below.
SP descriptions
SP5-810-002 [SC Reset: Hard High Temp. Detection]
Clears the fusing hardware SC.
SP3-701-115 [Manual New Unit Set: #Fusing Unit]