EasyManua.ls Logo

NXP Semiconductors K22F series - UART Data Register (Uartx_D)

NXP Semiconductors K22F series
1407 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UARTx_C3 field descriptions (continued)
Field Description
4
TXINV
Transmit Data Inversion.
Setting this field reverses the polarity of the transmitted data output. In NRZ format, a one is represented
by a mark and a zero is represented by a space for normal polarity, and the opposite for inverted polarity.
In IrDA format, a zero is represented by short high pulse in the middle of a bit time remaining idle low for a
one for normal polarity, and a zero is represented by short low pulse in the middle of a bit time remaining
idle high for a one for inverted polarity.This field is automatically set when C7816[INIT] and
C7816[ISO7816E] are enabled and an initial character is detected in T = 0 protocol mode.
NOTE:
Setting TXINV inverts all transmitted values, including idle, break, start, and stop bits. In loop
mode, if TXINV is set, the receiver gets the transmit inversion bit when RXINV is disabled. When
C7816[ISO7816E] is set/enabled then only the transmitted data bits and parity bit are inverted.
0 Transmit data is not inverted.
1 Transmit data is inverted.
3
ORIE
Overrun Error Interrupt Enable
Enables the overrun error flag, S1[OR], to generate interrupt requests.
0 OR interrupts are disabled.
1 OR interrupt requests are enabled.
2
NEIE
Noise Error Interrupt Enable
Enables the noise flag, S1[NF], to generate interrupt requests.
0 NF interrupt requests are disabled.
1 NF interrupt requests are enabled.
1
FEIE
Framing Error Interrupt Enable
Enables the framing error flag, S1[FE], to generate interrupt requests.
0 FE interrupt requests are disabled.
1 FE interrupt requests are enabled.
0
PEIE
Parity Error Interrupt Enable
Enables the parity error flag, S1[PF], to generate interrupt requests.
0 PF interrupt requests are disabled.
1 PF interrupt requests are enabled.
47.3.8 UART Data Register (UARTx_D)
This register is actually two separate registers. Reads return the contents of the read-only
receive data register and writes go to the write-only transmit data register.
NOTE
In 8-bit or 9-bit data format, only UART data register (D)
needs to be accessed to clear the S1[RDRF] bit (assuming
receiver buffer level is less than RWFIFO[RXWATER]).
The C3 register needs to be read, prior to the D register,
Chapter 47 Universal Asynchronous Receiver/Transmitter (UART)
K22F Sub-Family Reference Manual, Rev. 4, 08/2016
NXP Semiconductors 1235

Table of Contents