Table 13-47. Kinetis Flashloader Status Error Codes, sorted by Value (continued)
Error Code Value Description
kStatus_I2C_AribtrationLost 202 I2C Arbitration Lost error.
kStatus_SPI_SlaveTxUnderrun 300 SPI Slave TX Underrun error.
kStatus_SPI_SlaveRxOverrun 301 SPI Slave RX Overrun error.
kStatus_SPI_Timeout 302 SPI tranfser timed out.
kStatus_SPI_Busy 303 SPI instance is already busy performing a transfer.
kStatus_SPI_NoTransferInProgress 304 Attempt to abort a transfer when no transfer was in
progress.
kStatus_UnknownCommand 10000 The requested command value is undefined.
kStatus_SecurityViolation 10001 Command is disallowed because flash security is
enabled.
kStatus_AbortDataPhase 10002 Abort the data phase early.
kStatusMemoryRangeInvalid 10200 Memory range conflicts with a protected region.
kStatus_UnknownProperty 10300 The requested property value is undefined.
kStatus_ReadOnlyProperty 10301 The requested property value cannot be written.
kStatus_InvalidPropertyValue 10302 The specified property value is invalid.
kStatus_AppCrcCheckPassed 10400 CRC check is valid and passed.
kStatus_AppCrcCheckFailed 10401 CRC check is valid but failed.
kStatus_AppCrcCheckInactive 10402 CRC check is inactive.
kStatus_AppCrcCheckInvalid 10403 CRC check is invalid, because the BCA is invalid or
the CRC parameters are unset (all 0xFF bytes).
kStatus_AppCrcCheckOutOfRange 10404 CRC check is valid but addresses are out of range.
Kinetis Flashloader Status Error Codes
K22F Sub-Family Reference Manual, Rev. 4, 08/2016
340 NXP Semiconductors