Chapter 16: LPC176x/5x CAN1/2
16.16.3.2 Scenario 2: Message lost
In this scenario a first FullCAN Message is stored and read out by Software (1
st
Object
write and read). In a second course a second message is stored (2
nd
Object write) but not
read out before a third message gets stored (3
rd
Object write). Since the FullCAN Interrupt
of that Object (IntPndx) is already asserted, the Message Lost Signal gets asserted.
Fig 65. Normal case, no messages lost
01 11
IntPndx
semaphore
bits
look-up
table
access
00
MsgLostx
message
handler
access
ARM
processor
access
read
SEM
read
D2
read
D1
clear
SEM
read
SEM
write
SEM
write
D2
write
D1
Write
ID, SEM
Fig 66. Message lost
01 11
01 11 1100
1st Object
write
2nd Object
write
1st Object
read
3rd Object
write
IntPndx
semaphore
bits
look-up
table
access
MsgLostx
message
handler
access
ARM
processor
access
read
SEM
read
D2
read
D1
clear
SEM
read
SEM
write
SEM
write
D2
write
D1
write
ID,
SEM
write
SEM
write
D2
write
D1
write
ID,
SEM
write
SEM
write
D2
write
D1
write
ID,
SEM

Table of Contents

Other manuals for NXP Semiconductors LPC1768

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NXP Semiconductors LPC1768 and is the answer not in the manual?

NXP Semiconductors LPC1768 Specifications

General IconGeneral
BrandNXP Semiconductors
ModelLPC1768
CategoryMicrocontrollers
LanguageEnglish

Related product manuals