UM10360 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
User manual Rev. 3 — 19 December 2013 472 of 841
NXP Semiconductors
UM10360
Chapter 19: LPC176x/5x I2C0/1/2
19.10.8.6 State: 0x88
Previously addressed with own Slave Address. Data has been received and NOT ACK
has been returned. Received data will not be saved. Not addressed Slave mode is
entered.
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
19.10.8.7 State: 0x90
Previously addressed with General Call. Data has been received, ACK has been returned.
Received data will be saved. Only the first data byte will be received with ACK. Additional
data will be received with NOT ACK.
1. Read data byte from I2DAT into the Slave Receive buffer.
2. Write 0x0C to I2CONCLR to clear the SI flag and the AA bit.
3. Exit
19.10.8.8 State: 0x98
Previously addressed with General Call. Data has been received, NOT ACK has been
returned. Received data will not be saved. Not addressed Slave mode is entered.
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
19.10.8.9 State: 0xA0
A STOP condition or repeated START has been received, while still addressed as a
Slave. Data will not be saved. Not addressed Slave mode is entered.
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
19.10.9 Slave Transmitter states
19.10.9.1 State: 0xA8
Own Slave Address + Read has been received, ACK has been returned. Data will be
transmitted, ACK bit will be received.
1. Load I2DAT from Slave Transmit buffer with first data byte.
2. Write 0x04 to I2CONSET to set the AA bit.
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Set up Slave Transmit mode data buffer.
5. Increment Slave Transmit buffer pointer.
6. Exit