1-001-009 Bit Switch 9 0 1
bit 0
PDL Auto Detection timeout of jobs submitted
via USB or Parallel Port (IEEE 1284).
Disabled
(Immediatel
y)
Enabled
(10 seconds)
To be used if PDL auto-detection fails. A failure of PDL auto detection doesn't
necessarily mean that the job can't be printed. This bit switch tells the device
whether to time-out immediately (default) upon failure or to wait 10 seconds.
bit 1 DFU - -
bit 2 Job Cancel Disabled
(Not
cancelled)
Enabled
(Cancelled)
If this bit switch, all jobs will be cancelled after a jam occurs.
Note: If this bitsw is enabled, printing under the following conditions might
result in problems:
- Job submission via USB or Parallel Port
- Spool printing (WIM >Configuration > Device Settings > System)