44 The data to be overwritten cannot
be accessed when controller-
related programs are
downloaded.
Switch the main power supply off and on to
try again.
Install the correct ROM update data in the
SD card.
Replace the controller board if the data to
be overwritten is contained on the controller
board.
49 Firmware updates are currently
prohibited.
The setting of Update Firmware in the
Administrator Tools has been set to [Prohibit]
by an administrator. Amend the setting to
[Do not Prohibit] and try again.
50 The results of the electronic
authorization check have rejected
the update data.
Install the correct ROM update data in the
SD card.
57 @Remote is not connected at the
date/time reserved for receiving
the package firmware update
from the network.
Check the @Remote connection.
58 Update cannot be done due to a
reception route problem.
Check the @Remote connection.
59 HDD is not mounted. Check the HDD connection.
60 HDD could not be used during the
package firmware update.
Try again.
Replace the HDD if the download fails
again.
61 The module ID for the package
firmware update is incorrect.
Prepare the correct package files.
62 The configuration of the package
firmware update files is incorrect.
Prepare the correct package files.
63 Reception fails due to the power
off at the reserved date/time of
the remote firmware update from
the network.
Update is to be done automatically when
the next reception time has elapsed.