SC No. Type Error Name/Error Condition/Major Cause/Solution
SC324-01 D Development motor: Bk: Lock
Motor status is observed at 100ms intervals during motor ON, and the
unlock status is detected at least 20 times
Motor defective
Connector disconnected
Harness broken
IOB defective
Development unit torque increased
Replace the motor
Reconnect the connector
Replace the harness
Replace the Imaging IOB.
Replace the development unit
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC324-05 D Development motor: CMY: Lock
Motor status is observed at 100ms intervals during motor ON, and the
unlock status is detected at least 20 times.
Motor defective
Connector disconnected
Harness broken
IOB defective
Development unit torque increased
Replace the motor
Reconnect the connector
Replace the harness
Replace the Imaging IOB.
Replace the development unit