EasyManua.ls Logo

Ricoh MP C2504 - Page 803

Ricoh MP C2504
1923 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC324-01 D Development motor: Bk: Lock
Motor status is observed at 100ms intervals during motor ON, and the
unlock status is detected at least 20 times
• Motor defective
• Connector disconnected
• Harness broken
• IOB defective
• Development unit torque increased
• Replace the motor
• Reconnect the connector
• Replace the harness
• Replace the Imaging IOB.
• Replace the development unit
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC324-05 D Development motor: CMY: Lock
Motor status is observed at 100ms intervals during motor ON, and the
unlock status is detected at least 20 times.
• Motor defective
• Connector disconnected
• Harness broken
• IOB defective
• Development unit torque increased
• Replace the motor
• Reconnect the connector
• Replace the harness
• Replace the Imaging IOB.
• Replace the development unit
6. Troubleshooting
794