SC No. Type Error Name/Error Condition/Major Cause/Solution
After starting continuous job with paper width of 257 mm or more, does
not reach 0 degrees C after 100 sec.
Outside input voltage guarantee
Thermistor dirt
Thermistor modification/float
After excessive temperature rise prevention unit operation
Fusing lamp disconnection
Harness disconnection between the fusing unit and the BCU or the
PSU (AC controller board)
Thermopile defective
BCU defective
AC controller board defective
1. Check the power supply voltage and reconnect the cable to the
outlet.
2. Clean or replace the thermistor.
3. Replace the fusing sleeve thermostat.
4. Replace the fusing sleeve belt unit.
5. Replace the harness between the fusing unit and the BCU or the PSU
(AC controller board).
6. Replace the thermopile (edge).
7. Replace the BCU.
8. Replace the PSU (AC controller board).
6. Troubleshooting
850

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP C2504 and is the answer not in the manual?

Ricoh MP C2504 Specifications

General IconGeneral
Print TechnologyLaser
FunctionsPrint, Copy, Scan, Fax
Print Resolution1200 x 1200 dpi
Scan TypeFlatbed, ADF
Max Scan Resolution600 x 600 dpi
Copy Resolution600 x 600 dpi
Max Paper SizeA3
Duplex PrintingYes
Memory (RAM)2 GB
Print Speed25 ppm (A4)
Copy Speed25 cpm (A4)
Fax Resolution200 x 200 dpi
Paper Capacity1200 sheets
ConnectivityUSB, Ethernet, Wi-Fi
Dimensions587 x 685 x 913 mm
Control Panel9-inch Smart Operation Panel

Related product manuals