SC No. Type Error Name/Error Condition/Major Cause/Solution
SC is displayed when unexpected reset from Imaging IOB/Paper
Transport IOB is detected while standby/operation.
• Unexpected noise from inside the machine gets into Paper Transport
IOB.
• Parts defect and implementation defect of Imaging IOB/ Paper
Transport IOB.
• Software ran reset to ASIC when there was a bug in the software or
unexpected signal was input (-03/-13 only).
1. Turn the main power OFF/ON.
2. Replace the Paper Transport IOB (-01 to -03)
3. Replace the Imaging IOB (-11 to -13)
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC664-01 D VODKA1 (Paper Transport Vodka) access permission error to VODKA
SRAM
SC664-02 D VODKA1 (Paper Transport Vodka) write error to VODKA SRAM
SC664-03 D VODKA1 (Paper Transport Vodka) VODKA program launch error
SC664-11 D VODKA2 (Imaging Vodka) access permission error to VODKA SRAM
SC664-12 D VODKA2 (Imaging Vodka) write error to VODKA SRAM
SC664-13 D VODKA2 (Imaging Vodka) VODKA program launch error
Service Call 620-687