SC No. Type Error Name/Error Condition/Major Cause/Solution
SC650-14 C Remote Service Modem Communication Error (RC Gate Type N was
installed but modem is present or wired/wireless LAN is not working
correctly)
An error related to communication (dialup connection, modem
board etc.) using the RC Gate was detected or an error that
prevents RC Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is
operating.
SC is not issued if an error occurs during RC Gate installation
(because it can be referenced using SP).
RC Gate Type N was installed but modem is present or wired/wireless
LAN is not working correctly
If a modem board is attached, remove it.
Check if wired/wireless LAN works.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC651-01 C Illegal Remote Service Dial-up (Chat program parameter error)
An unexpected error occurred when RC Gate Type M dialed up the NRS
Center.
Software bug
Logging only.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC651-02 C Illegal Remote Service Dial-up (Chat program execution error)
An unexpected error occurred when RC Gate dialed up the NRS Center.
Software bug
Logging only.
Service Call 620-687