EasyManua.ls Logo

Ricoh MP C2504 - Page 925

Ricoh MP C2504
1923 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Type Error Name/Error Condition/Major Cause/Solution
SC816-26
to 28
D
write() communication retry error
SC816-29
, 30
D
read() communication retry error
SC816-35 D read() error
SC816-36
to 96, 99
D
Subsystem error
Energy save I/O subsystem detected some abnormality.
Energy save I/O subsystem defective
Energy save I/O subsystem detected a controller board error (non-
response).
Error was detected during preparation for transition to STR.
SC816-99 occurs as a subsystem error except any error from -06 to
96.
Check if the SC occurs by turning the power OFF then ON. If the SC
occurs again, do the following steps. Check if the SC reoccurs by cycling
the power after each step.
1. Update the "System/Copy" firmware and the other system firmware
modules to the latest version.
2. Disable the STR shift function by SP5-191-001 (Power Str Set).
3. Replace the controller board.
6. Troubleshooting
916

Table of Contents

Related product manuals