EasyManua.ls Logo

Ricoh MP C2504 - Page 926

Ricoh MP C2504
1923 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Type Error Name/Error Condition/Major Cause/Solution
SC817-00 D Monitor error: File detection / Digital signature error
Bootloader cannot read any of diagnostic module, kernel, or root
filesystem.
In a bootloader SD card, the digital signature checking for any of
diagnostic module, kernel, or root filesystem is failed.
Any of the following items does not exist or is broken OS Flash ROM,
Diagnostic module in SD card, Kernel, Root filesystem
Any of the following items is revised fraudulently: Diagnostic module
in SD card, Kernel, Root filesystem
ROM update for controller system
Use another booting SD card having a valid digital signature
No. Type Error Name/Error Condition/Major Cause/Solution
SC818-00 D Watchdog timer error
The system program fell into a bus-hold state or an endless loop of the
program interruption occurred, causing other process to stop.
System program defective
Controller board defective
Optional board defective
Turn the main power OFF/ON.
Replace the controller board.
No. Type Error Name/Error Condition/Major Cause/Solution
SC819-00 D Kernel halt error
[xxxx]: Detailed error code
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on the
operation panel.
Service Call 816-899
917

Table of Contents

Related product manuals