No. Type Error Name/Error Condition/Major Cause/Solution
SC876-01 D Log Data Error 1
An error was detected in the handling of the log data at power on or
during machine operation.
Damaged log data file
Initialize the HDD (SP5-832-004).
No. Type Error Name/Error Condition/Major Cause/Solution
SC876-02 D Log Data Error 2
An error was detected in the handling of the log data at power on or
during machine operation.
Log encryption is enabled but encryption module is not installed.
• Replace or set again the encryption module.
• Disable the log encryption setting.
No. Type Error Name/Error Condition/Major Cause/Solution
SC876-03 D Log Data Error 3
An error was detected in the handling of the log data at power on or
during machine operation.
Inconsistency of encryption key between NV-RAM and HDD.
• Disable the log encryption setting.
• Initialize LCS memory (SP5801-019).
• Initialize the HDD (SP5-832-004).