UM10360 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
User manual Rev. 3 — 19 December 2013 586 of 841
NXP Semiconductors
UM10360
Chapter 30: LPC176x/5x Digital-to-Analog Converter (DAC)
If either the CNT_ENA or the DBLBUF_ENA bits are 0, any writes to the DACR address
will go directly to the DACR register.
Fig 133. DAC control with DMA interrupt and timer
CNTVAL
COUNTER
PRE-BUFFER
MUX
DACR
LD
LD
LDEN
16
16
pbus
pbus
set_intrpt
dblbuf_ena
cnt_ena
ena_cnt_and_dblbuf
pbus_wr_to_DACR
1
0
pbus
pbus
pbus_wr_toDACR
zero
DAC value
3
2
1
0
S
C
set_intrpt
pbus
pbus_wr_to_DACR
DMA_ena
intrptDMA_req