SC No. Type Error Name/Error Condition/Major Cause/Solution
SC723 Internal Finisher SR3180 (D766) Error
SC723-03 B Power Supply Error
When original source 24V power supply is ON, protection device
intercept of non-interlock power supply system is detected.
A motor failure or harness short-circuit occur in the non-interlock power
supply system.
Replace the short-circuited harnesses
Replace the protection devices
SC723-10 B Transport Motor Error
The DCM driver error detection is started after reset, and the error signal
is detected for 0.2 sec.
This SC will be issued when the above phenomenon repeated 2 times.
Transport Motor failure
Harness short-circuit
Circuit board failure
Over current
Abnormal temperature
Replace the motor
Replace the harness
Replace the circuit board.
Service Call 700-792
903